GALAXY® GX2 Automated Test System
2 Part Number(s)
Simplicity counts with the MSA GALAXY® GX2 Automated Test System for advanced safety management and effortless operation. The GALAXY GX2 Automated Test System provides simple, intelligent testing and calibration of MSA ALTAIR® and ALTAIR PRO Single-Gas Detectors and ALTAIR 4X and ALTAIR 5X Multigas Detectors. Easy-to-use automated test stand offers high performance as either stand-alone unit or integrated portable detector management system, enabling total data access and control of the MSA ALTAIR family Gas Detector fleet. New MSA Link™ Pro Software for proactive safety management; gas exposure email alerts, direct data input, live filtering, test and exposure queries, collecting and printing reports.
Featured
V-Gard 950 Non-Vented Protective Cap
8 Part Number(s)
Balanced and lightweight electrician's safety helmet, non-vented, with 6-point Fas-Trac® III ratchet suspension, GS-ET-29 class 1 (4kA) face shield certified for protection against arc flash. For use where top impact hazards to the head, chemical splash, Ultra-Violet radiation, molten metal splash or electric arc to the face exist.
GA90033
Arc-flash ear-flaps VG900 (pair)
GA90034
Faceshield VG950
GVF1A-80A0000-000
HELMET,V-GARD 950,NV,WHT,FTIII+F
GVF2A-80A0000-000
Helmet,V-Gard 950,NV,yel,FTIII+F
GVF3A-80A0000-000
Helmet,V-Gard 950,NV,red,FTIII+F
GVF4A-80A0000-000
Helmet,V-Gard 950,NV,grn,FTIII+F
GVF5A-80A0000-000
Helmet,V-Gard 950,NV,blu,FTIII+F
GVF6A-80A0000-000
Helmet,V-Gard 950,NV,orn,FTIII+F
Featured
Advantage® 420 Half-Mask Respirator
4 Part Number(s)
With its UniBond over-mold facepiece, AnthroCurve™ face seal, and low profile design, the Advantage 420 Respirator is the superior option for respiratory protection. The over-mold facepiece and face seal ensure the unit provides an excellent fit and comfort to the wearer. The unique yoke and harness design (patent pending) allows a user to easily don and doff the state-of-the-art respirator while maintaining a customized fit. Other features include a ComforTop headband, a built-in moisture release chin cup hole, and the extra-wide head and neck straps.
Featured
IR400 Point IR Gas Detector
1 Part Number(s)
The IR400 Infrared (IR) Point Detector is a hydrocarbon gas detector that continuously monitors combustible gases and vapors within the lower explosive limit (LEL) and provides alarm indication. It features an industry-leading response time of ≤ 3 seconds, even with a splash guard installed. All electronics are contained within an explosion-proof housing so that the IR400's detector information can be processed locally. Configurations with analog output, Modbus and HART are also available.
Featured
V-Gard® Visors PC for General Purpose
8 Part Number(s)
MSA polycarbonate visors reliably protect against impact, chemical splash and UltraViolet radiation. They are the perfect solution for general and basic applications and can be worn with helmet-mounted ear muffs.
10115836
VISOR,.V-GARD,PC,CLR,SHxSTDxLTW
10115837
VISOR,.V-GARD,PC,CLR,SHxSTDxLTW,NITRO
10115839
VISOR,.V-GARD,PC,CLR,AFAS,SHxSTDxTHK
10115840
VISOR,V-GARD,PC,CLR,SHxSTDxTHK
10115841
VISOR,V-GARD,PC,CLR,SHxSTDx.060 THK
10115843
VISOR,V-GARD,PC,GN,AFAS,SHxSTDx.060 THK
10115863
VISOR,V-GARD,PC,CLR,MEDxSTDxLTW
10117783
VISOR,V-GD,SHxSTxTHK,CHN,NON CSA, .060
Featured
HazardWatch Fire and Gas System
1 Part Number(s)
An innovative, modular system that combines highly reliable programmable logic controller (PLC) technology with our advanced gas and flame field devices. It is highly scalable, making it suitable for small systems to large plant-wide applications. Offering intelligence, flexibility and reliability, the HazardWatch System's controller hardware configuration and software has been tested by Factory Mutual to verify NFPA 72 compliance.
Featured
Advantage® 3100 Full-Facepiece Respirator
5 Part Number(s)
The full face mask series Advantage 3000 provides both protection and unparalleled comfort. The soft sealing line made of hypoallergenic silicone provides a pressure free fit.
The large, optically corrected lens ensures a clear, undistorted view, while the grey-blue colour gives the mask an aesthetic appearance.
Donning the Advantage 3000 is unbelievably quick, simple and accomplished without painful hair pulling. The patented Advantage head harness gives a perfect face piece-to-face fit.
Featured
FL4000H Multi-spectrum IR Flame Detector
1 Part Number(s)
The FL4000H is an advanced multi-spectrum infrared (MSIR) flame detector that provides superior false alarm immunity with the widest field of view. The FL4000H employs a multi-spectral optical IR sensing array with a sophisticated Neural Network Technology (NNT) system to reliably discriminate between actual flames and the vast majority of false alarm sources. The FL4000H detects typical fires such as alcohol, n-heptane, gasoline, jet fuels and hydrocarbons. It can also see through dense smoke produced by diesel, rubber, plastics and lube oil fires.
Featured
FL500 UV/IR Flame Detector
1 Part Number(s)
The FL500 UV/IR Flame Detector monitors for radiation emitted by a flame in both the ultraviolet (UV) and infrared (IR) spectral ranges. This UV/IR combination provides a fast response time and increased false alarm immunity against sources of radiation for reliable protection.
Advantage® 410 Half-Mask Respirator
3 Part Number(s)
This innovative half-mask respirator features MSA's patent-pending, single-loop head harness and user-friendly design. Easy to don, doff, or drop down, it contains just three major components, making it extra easy to clean. The one-piece MultiFlex nose cup is made of soft, smooth, co-molded silcone and rigid plastic for a unique combination of durability and comfort.