Featured
IR400 Point IR Gas Detector
1 Part Number(s)
The IR400 Infrared (IR) Point Detector is a hydrocarbon gas detector that continuously monitors combustible gases and vapors within the lower explosive limit (LEL) and provides alarm indication. It features an industry-leading response time of ≤ 3 seconds, even with a splash guard installed. All electronics are contained within an explosion-proof housing so that the IR400's detector information can be processed locally. Configurations with analog output, Modbus and HART are also available.
Featured
HazardWatch Fire and Gas System
1 Part Number(s)
An innovative, modular system that combines highly reliable programmable logic controller (PLC) technology with our advanced gas and flame field devices. It is highly scalable, making it suitable for small systems to large plant-wide applications. Offering intelligence, flexibility and reliability, the HazardWatch System's controller hardware configuration and software has been tested by Factory Mutual to verify NFPA 72 compliance.
Featured
FL4000H Multi-spectrum IR Flame Detector
1 Part Number(s)
The FL4000H is an advanced multi-spectrum infrared (MSIR) flame detector that provides superior false alarm immunity with the widest field of view. The FL4000H employs a multi-spectral optical IR sensing array with a sophisticated Neural Network Technology (NNT) system to reliably discriminate between actual flames and the vast majority of false alarm sources. The FL4000H detects typical fires such as alcohol, n-heptane, gasoline, jet fuels and hydrocarbons. It can also see through dense smoke produced by diesel, rubber, plastics and lube oil fires.
Featured
FL500 UV/IR Flame Detector
1 Part Number(s)
The FL500 UV/IR Flame Detector monitors for radiation emitted by a flame in both the ultraviolet (UV) and infrared (IR) spectral ranges. This UV/IR combination provides a fast response time and increased false alarm immunity against sources of radiation for reliable protection.
Discontinued
FireHawk® M7XT Air Mask
2 Part Number(s)
Through NFPA, firefighters strive to improve the durability and performance of their SCBA and PASS devices. It's no different with the new 2013 edition of NFPA 1981 and 1982 NFPA standards for self-contained breathing apparatus and personal alert safety systems (PASS). These revisions call for a minimum low pressure alarm set point of 33% cylinder operating pressure remaining, improved facepiece lens radiant heat performance, 500° F heat and flame exposure, and standardized PASS device alarm sound patterns.
In addition, NFPA has raised the bar on voice communication capability, now requiring measurable, minimum Sound Transmission Index (STI) scores for both mechanical and electronic communications.
MSA's new FireHawk M7XT Air Mask represents a true technological achievement in critical firefighter protection.
As firefighters determined the safety requirements required to meet NFPA 1981 and 1982 2013-edition standards, MSA engineering teams began to design solutions. The new FireHawk M7XT Air Mask, with its life-safety design components built upon a modular air mask platform, exceeds NFPA 2013 requirements and provides firefighters with the highest quality SCBA available.
TA402A Single Channel Trip Amplifier
1 Part Number(s)
The Model TA402A is a single-channel trip amplifier module designed for use with the FL3100 Series Flame Detectors, providing status indication and alarm outputs.
Discontinued
FireHawk® M7 Air Mask
22 Part Number(s)
This advanced air mask features seven life-safety design components. It is the highest quality SCBA available and is virtually bulletproof against fire ground hazard. Although lightweight and easy to use, it's a stellar performer—even in the face of extreme temperatures (up to 500°F).
10091242
A-M7-LD13A0-C14AA-1
10091243
A-M7-HD14A0-C14AA-1
10095009
B-M7H-D04-A0C14-AAA1
10095261
B-M7L-D03-A0C14-AAA1
10113986
A-M7H-D-1-4-B-0-D-2-4-A-A-1
10114535
B-M7H-D14B-0C14-AAA1
10114536
B-M7L-D-1-3-B-0-C-1-4-A-A-A-1
10115095
A-M7H-D-1-1-B-0-C-1-4-A-A-1
10125439
FIREHAWK, M7 AIR MASK, 2216, CONFIGURED
10125443
FIREHAWK, M7 AIR MASK, 4500, CONFIGURED
10143926
SAR/SELF CONTAINED, BREATHING AP
10145011
FIREHAWK M7 AIR MASK, 4500, CONFIGURED
10148704
SAR/SELF CONTAINED BREATHING AP
10149964
FIREHAWK M7 AIR MASK, 2216, CONFIGURED
10149971
FIREHAWK M7 AIR MASK, 4500, CONFIGURED
10153097
M7 CONFIGURED
10153536
FIREHAWK M7 AIR MASK ,2216, CONFIGURED
10154097
FIREHAWK M7 AIR MASK, 4500, CONFIGURED
10154131
FIREHAWK M7 AIR MASK, 4500, CONFIGURED
10155429
SCBA,AIRHAWK II,4500 PSIG,CONFIGURED
10155488
SCBA,AIRHAWK II,2216 PSIG CONFIGURED
10157893
FIREHAWK M7 AIR MASK, 4500, CONFIGURED
TA202A Single Channel H2S Trip Amplifier Module
1 Part Number(s)
The TA202A is a single-channel H2S Trip Amplifier Module for use with our H2S Intelligent Sensors. It is designed to monitor H2S in parts per million (ppm) levels and provide status indication and alarm outputs. Microprocessor-based electronics allow all options to be user selectable through front panel interface (mode / select switch and digital display).
DT210 Eight Channel H2S Readout / Relay Module
1 Part Number(s)
The DT210 is an eight-channel Readout / Relay Module designed for use with up to eight of our remotely located H2S Intelligent Sensors. The front panel contains a digital display that indicates 0-20 ppm (parts per million), 0-50 ppm, or 0-99 ppm of the hydrogen sulfide gas monitored by the Intelligent Sensors.
Toxic Gas Accessories
15 Part Number(s)
General Monitors offers a wide variety of accessories for our toxic gas detectors.
10252-1
Sensor housing
1400263-x
TS-Series calibration gas kit
31305-1
Junction box w/zero switch
31305-2
Junction box w/out zero switch
31306-1
IR duct mount junction box
31420-1
IR flow block
31465-1
IR700 splash guard
31466-1
IR700 remote gas/screen splash guard
31478-1
IR700 calibration gas kit
31545-1
IR rain guard
45081-1
TS-Series dust guard
45160-1
Junction box (Hawke type)
45167-1
TS Series splash guard for CL2, CL02, O3 only
45170-1
TS-Series flow block assembly
70631-2
TS-Series splash guard